To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN 61643-11:2013-04

VDE 0675-6-11:2013-04

Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods (IEC 61643-11:2011, modified); German version EN 61643-11:2012

German title
Überspannungsschutzgeräte für Niederspannung - Teil 11: Überspannungsschutzgeräte für den Einsatz in Niederspannungsanlagen - Anforderungen und Prüfungen (IEC 61643-11:2011, modifiziert); Deutsche Fassung EN 61643-11:2012
Publication date
2013-04
Original language
German
Pages
101

Please select

162.14 EUR VAT included

151.53 EUR VAT excluded

Purchasing options

Shipment (3-5 working days) 1
  • 162.14 EUR

1

 Attention: Document withdrawn!

Publication date
2013-04
Original language
German
Pages
101

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard describes safety and performance tests for surge protective devices (SPDs). There are three classes of tests: - The Class I test simulates partial conducted lightning current impulses. - SPDs subjected to Class I test methods are generally recommended for locations at points of high exposure, for example, line entrances to buildings protected by lightning protection systems. - SPDs tested to Class II or III test methods are subjected to impulses of shorter duration. SPDs are tested on a "black box" basis as far as possible. IEC 61643-12 describes the selection and application principles of SPDs in practical situations. This part of EN 61643 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50 Hz a.c. power circuits, and equipment rated up to 1 000 V r.m.s. Performance characteristics, safety requirements, standard methods for testing and ratings are specified. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents. The responsible committee is Subcommittee UK 441.1 "Starkstromkabel" ("Power cables") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...