DIN EN 50152-3-2:2016-11

VDE 0115-320-3-2:2016-11

Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers; German version EN 50152-3-2:2016

German title
Bahnanwendungen - Ortsfeste Anlagen - Besondere Anforderungen an Wechselstrom-Schalteinrichtungen - Teil 3-2: Mess-, Steuerungs- und Schutzeinrichtungen für Wechselstrom-Bahnanlagen - Stromwandler; Deutsche Fassung EN 50152-3-2:2016
Publication date
2016-11
Original language
German
Pages
17

Please select

48.74 EUR VAT included

45.55 EUR VAT excluded

Purchasing options

Shipment (3-5 working days)
  • 48.74 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2016-11
Original language
German
Pages
17

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard applies to current transformers designed for indoor or outdoor fixed installations in electric traction power supply systems and operated with an overhead contact line AC voltage and frequency in accordance with EN 50163. EN 50163 specifies the a.c. traction systems 15 kV 16,7 Hz and 25 kV 50 Hz. As rails of a.c. traction systems are connected to earth and included in the return current path all phase to earth voltages will be within the tolerances as specified in EN 50163. Nevertheless, phase to phase voltages may be higher in some cases, for example in autotransformer systems. The current transformers covered by this draft standard are mainly used with measuring instruments and protective devices. This standard shall also be applied to current transformers other than inductive types as far as reasonably possible. Requirements of this draft have priority. The responsible committee is DKE/UK 351.2 "Ortsfeste Anlagen" ("Fixed installations") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.