&nbsp
International Customer Service
Phone +49 30 2601-2759
Fax +49 30 2601-1263

Standard [CURRENT]

DIN 18560-4:2012-06

Floor screeds - Part 4: Screeds laid on separated layer

German title
Estriche im Bauwesen - Teil 4: Estriche auf Trennschicht
Publication date
2012-06
Original language
German

Please select

from 55.55 EUR VAT included

from 52.90 EUR VAT excluded

Purchasing options

PDF download
  • 55.55 EUR

(3-5 working days) Shipment
  • 67.02 EUR

Subscription 1
Publication date
2012-06
Original language
German
DOI
https://dx.doi.org/10.31030/1889981

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice 

All transactions are encrypted

Overview

This standard applies in conjunction with DIN EN 13813 and DIN 18560-1 for screeds which are separated from the base by a thin separating layer. These screeds are intended to make the surface of a layer useable. They can be used directly (without covering) or they can be used with a covering. For screeds on top of a separating layer which are subjected to high stresses, DIN 18560-4 shall be considered. The standards of the DIN 18560 series have been revised by Working Committee NA 005-09-75 AA "Estriche im Bauwesen" ("Screed in building") of NABau due to the publication of the revised DIN 18560-1 and DIN 18560-2. DIN 18560 consists of: Part 1: General requirements, testing and construction; Part 2: Floor screeds and heating floor screeds on insulation layers; Part 3: Bonded screed; Part 4: Screeds laid on separated layer; Part 7: Heavy-duty screeds (industrial screeds). The following modifications have been made with respect to DIN 18560-4:2004-04: a) the normative references have been updated; b) regulations on screed thicknesses (3.2 and Table 1) have been revised; c) regulations on strength classes and hardness classes (3.3 and Table 2) have been revised; d) constructional requirements for welding lines and screed joints have been revised; e) moisture measurement with a moisture measurement system has been incorporated; f) specifications on separating layers (6.1) have been specified in more detail; g) thickness of the separating layer made of polyethylene foil has been increased to 0,15 mm; h) specifications on surface layer have been incorporated (6.3); i) examples for designations of screed have been incorporated (clause 7); j) example for recording of a moisture measurement has been incorporated as informative Annex A; k) document has been adopted to the current design rules.

Content
DOI
https://dx.doi.org/10.31030/1889981
Amendments

Cooperation at DIN

Your contact person

Also available in
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...