To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN ISO 15197:2013-11

In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013); German version EN ISO 15197:2013

German title
Testsysteme für die In-vitro-Diagnostik - Anforderungen an Blutzuckermesssysteme zur Eigenanwendung bei Diabetes mellitus (ISO 15197:2013); Deutsche Fassung EN ISO 15197:2013
Publication date
2013-11
Original language
German
Pages
59

Please select

from 141.20 EUR VAT included

from 131.96 EUR VAT excluded

Purchasing options

PDF download 1
  • 141.20 EUR

  • 176.50 EUR

Shipment (3-5 working days) 1
  • 170.60 EUR

  • 213.40 EUR

1

 Attention: Document withdrawn!

Online service subscriptions

This document also features in an online service. Online services not only give you electronic access to collections of standards, they contain lots of extra information too (such as directives, legal texts, commentaries, etc.). There are automatic updates on a regular basis – and online services also give you large savings compared with the cost of purchasing standards individually.

Suitable online services
Publication date
2013-11
Original language
German
Pages
59

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard is the result of the revision of DIN EN ISO 15197:2004. At international level, the work had been done by ISO/TC 212 and CEN/TC 140. At national level, the responsible committee is NA 063-03-11 AA "Patientennahe Sofortdiagnostik (POCT)" ("Point-of-care-testing (POCT)"). Blood-glucose monitoring systems are in vitro diagnostic medical devices used predominantly by individuals affected by diabetes mellitus. Diabetes mellitus is caused by a deficiency in insulin secretion or by insulin resistance leading to abnormally high concentrations of glucose in the blood, which may result in acute and chronic health complications. When used properly, a glucose monitoring system allows the user to monitor and take action to control the concentration of glucose present in the blood. This International Standard is intended for blood-glucose monitoring systems used by lay persons. The primary objectives are to establish requirements that result in acceptable performance and to specify procedures for demonstrating conformance to this International Standard. Requirements that are unique to self-monitoring devices for blood-glucose are addressed in this standard. The revised performance criteria in this edition are the result of improvements in technology since publication of the previous edition. This standard specifies requirements for in vitro glucose monitoring systems that measure glucose concentrations in capillary blood samples, for specific design verification procedures and for the validation of performance by the intended users. These systems are intended for self-measurement by lay persons for management of diabetes mellitus. The document is applicable to manufacturers of such systems and those other organizations (for example regulatory authorities and conformity assessment bodies) having the responsibility for assessing the performance of these systems.

Content
ICS
11.100.10
Replacement amendments

This document replaces DIN EN ISO 15197:2013-09 .

This document has been replaced by: DIN EN ISO 15197:2015-12 .

Corrected edition: Corrected document: Customers who purchased the previous document DIN EN ISO 15197:2013-09 received free of charge