To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [AVAILABLE PRE-PUBLICATION]

DIN EN 14662-1:2024-05

Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography; German version EN 14662-1:2023

German title
Außenluft - Verfahren zur Messung von Benzolkonzentrationen - Teil 1: Probenahme mit einer Pumpe, gefolgt von Thermodesorption und Gaschromatographie; Deutsche Fassung EN 14662-1:2023
Publication date
2024-05
Original language
German
Pages
74

Please select

from 163.40 EUR VAT included

from 152.71 EUR VAT excluded

Purchasing options

PDF download
  • 163.40 EUR

  • 196.10 EUR

  • 204.30 EUR

Shipment (3-5 working days)
  • 197.40 EUR

  • 246.80 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2024-05
Original language
German
Pages
74
DOI
https://dx.doi.org/10.31030/3505859

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography. This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m3 to 50 μg/m3 in an air sample typically collected over a period of 24 hours. The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents. The detection limit will be approximately 1/10 of the lower concentration range.Expansion of Scope: This part of EN 14662 provides general guidance for the sampling of benzene using either a single sampler, which is changed manually after every exposure period, or a multi-tube sampler capable of storing and exposing multiple samples sequentially without user intervention.
Content
ICS
13.040.20
DOI
https://dx.doi.org/10.31030/3505859
Replacement amendments

This document replaces DIN EN 14662-1:2005-08 .

And replaced by 2024-05 for:: DIN EN 14662-1:2005-08 , DIN EN 14662-1:2022-09 .

Document timeline
PRE-PUBLISHED
2024-05

Standard [AVAILABLE PRE-PUBLICATION]

DIN EN 14662-1:2024-05
Drafts
2022-09 - 2024-05
intended to be withdrawn
2005-08 - 2024-05

Cooperation at DIN

Also available in
Loading recommended items...