Standard [WITHDRAWN]

DIN EN 50557:2012-08

VDE 0640-20:2012-08

Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses; German version EN 50557:2011

German title
Automatisch wiedereinschaltende Einrichtungen für Leitungsschutzschalter sowie Fehlerstrom-Schutzschalter mit und ohne eingebautem Überstromschutz (RCBOs und RCCBs) für Hausinstallationen und für ähnliche Anwendungen (ARDs); Deutsche Fassung EN 50557:2011
Publication date
2012-08
Original language
German
Pages
61

Please select

110.24 EUR VAT included

103.03 EUR VAT excluded

Purchasing options

Shipment (3-5 working days) 1
  • 110.24 EUR

1

 Attention: Document withdrawn!

Publication date
2012-08
Original language
German
Pages
61

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard describes automatic reclosing devices for circuit breakers as well as residual current breakers with and without built-in over-current protection (RCBOs and RCCBs) for household and similar uses (ARDs), German Version EN 50557:2011. These devices are intended to reclose main protective devices (hereinafter referred to as "MPD") such as circuit-breakers complying to EN 60898-1 and/or EN 60898-2, RCCBs complying to EN 61008-1 and RCBOs complying to EN 61009-1 after tripping of those devices in order to re-establish continuity of service. In detail, this European Standard applies to the following types of ARDs: - ARDs with assessment means, reclosing only if both the prospective line current and the prospective earth-fault current do not exceed given values; - ARDs with assessment means, reclosing only if the prospective line current does not exceed a given value; - ARDs with assessment means, reclosing only if the prospective earth-fault current does not exceed a given value; - ARDs that reclose without any assessment. The responsible committee is Subcommittee DKE/UK 541.3 "Fehlerstrom-Schutzeinrichtungen" ("Residual current devices") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.