Standard [WITHDRAWN]

DIN EN ISO 11855-4:2016-11

Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 4: Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS) (ISO 11855-4:2012); German version EN ISO 11855-4:2015

German title
Umweltgerechte Gebäudeplanung - Planung, Auslegung, Installation und Steuerung flächenintegrierter Strahlheizungs- und -kühlsysteme - Teil 4: Auslegung und Berechnung der dynamischen Wärme- und Kühlleistung für thermoaktive Bauteilsysteme (TABS) (ISO 11855-4:2012); Deutsche Fassung EN ISO 11855-4:2015
Publication date
2016-11
Original language
German
Pages
63

Please select

from 146.40 EUR VAT included

from 136.82 EUR VAT excluded

Purchasing options

PDF download 1
  • 146.40 EUR

  • 182.90 EUR

Shipment (3-5 working days) 1
  • 177.10 EUR

  • 221.20 EUR

1

 Attention: Document withdrawn!

Online service subscriptions

This document also features in an online service. Online services not only give you electronic access to collections of standards, they contain lots of extra information too (such as directives, legal texts, commentaries, etc.). There are automatic updates on a regular basis – and online services also give you large savings compared with the cost of purchasing standards individually.

Suitable online services
Publication date
2016-11
Original language
German
Pages
63
DOI
https://dx.doi.org/10.31030/2568057

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

DIN EN ISO 11855-4 allows the calculation of peak cooling capacity of Thermo Active Building Systems (TABS), based on heat gains, such as solar gains, internal heat gains, and ventilation, and the calculation of the cooling power demand on the water side, to be used to size the cooling system, as regards the chiller size, fluid flow rate, etcetera. This part of DIN EN ISO 11855 defines a detailed method aimed at the calculation of heating and cooling capacity in non-steady state conditions. The DIN EN ISO 11855 series is applicable to water based embedded surface heating and cooling systems in residential, commercial and industrial buildings. The methods apply to systems integrated into the wall, floor or ceiling construction without any open air gaps. It does not apply to panel systems with open air gaps which are not integrated into the building structure. The DIN EN ISO 11855 series also applies, as appropriate, to the use of fluids other than water as a heating or cooling medium. The ISO 11855 series is not applicable for testing of systems. The methods do not apply to heated or chilled ceiling panels or beams. The committee responsible for this standard is NA 041-01-58 AA "Heizungsanlagen in Gebäuden (SpA CEN/TC 228)" ("Heating systems in buildings (mirror committee for CEN/TC 228)") at DIN.

Content
ICS
91.140.10, 91.140.30
DOI
https://dx.doi.org/10.31030/2568057
Replacement amendments

This document has been replaced by: DIN EN ISO 11855-4:2022-04 .

Corrected edition: Corrected document: Customers who purchased the previous document DIN EN ISO 11855-4:2015-11 received free of charge