To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

DIN EN ISO 15186-3:2010-12

Acoustics - Measurement of sound insulation in buildings and of building elements using sound intensity - Part 3: Laboratory measurements at low frequencies (ISO 15186-3:2002); German version EN ISO 15186-3:2010

German title
Akustik - Bestimmung der Schalldämmung in Gebäuden und von Bauteilen aus Schallintensitätsmessungen - Teil 3: Messungen bei niedrigen Frequenzen im Prüfstand (ISO 15186-3:2002); Deutsche Fassung EN ISO 15186-3:2010
Publication date
2010-12
Original language
German
Pages
20

Please select

from 77.90 EUR VAT included

from 72.80 EUR VAT excluded

Purchasing options

PDF download
  • 77.90 EUR

  • 97.50 EUR

Shipment (3-5 working days)
  • 94.00 EUR

  • 117.80 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2010-12
Original language
German
Pages
20
DOI
https://dx.doi.org/10.31030/1719230

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

ISO 15186-3 specifies a sound intensity method to determine the sound reduction index and the element-normalized level difference of building elements at low frequencies. This method has significantly better reproducibility in a typical test facility than those of ISO 140-3, ISO 140-10 and ISO 15186-1. The results are more independent of the room dimensions of the laboratory and closer to values that would be measured between rooms of volume greater than 300 m3. This part of ISO 15186 is applicable in the frequency range 50 Hz to 160 Hz but is mainly intended for the frequency range 50 Hz to 80 Hz. For elements faced with thick, porous absorbers, the recommended frequency range is to 50 Hz to 80 Hz. The main differences between the methods of ISO 15186-1 and ISO 15186-3 are that in ISO 15186-3 the sound pressure level of the source room is measured close to the surface of the test specimen, and the surface opposite the test specimen in the receiving room is highly absorbing and converts the room acoustically into a duct with several propagating cross-modes above the lowest cut-on frequency. The results found by the method of ISO 15186-3 can be combined with those of ISO 140-3 and ISO 15186-1 to produce data in the frequency range 50 Hz to 5 000 Hz. This test standard is directed at manufacturers of building acoustic test stands. The Committee responsible for this standard is NA 062-02-31 AA "Schalldämmung und Schallabsorption, Messung und Bewertung" ("Sound reduction and sound absorption, measurement and evaluation") at DIN.

Content
ICS
91.120.20
DOI
https://dx.doi.org/10.31030/1719230

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...