Technical rule [CURRENT]

DIN SPEC 58929:2012-08

Operation of small steam sterilizers in the health-care system - Guidance for validation and routine control of sterilization processes

German title
Betrieb von Dampf-Klein-Sterilisatoren im Gesundheitswesen - Leitfaden zur Validierung und Routineüberwachung der Sterilisationsprozesse
Publication date
2012-08
Original language
German
Pages
50
Procedure
Pre-Standard

Please select

from 103.40 EUR VAT included

from 96.64 EUR VAT excluded

Purchasing options

PDF download
  • 103.40 EUR

Shipment (3-5 working days)
  • 125.00 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Online service subscriptions

This document also features in an online service. Online services not only give you electronic access to collections of standards, they contain lots of extra information too (such as directives, legal texts, commentaries, etc.). There are automatic updates on a regular basis – and online services also give you large savings compared with the cost of purchasing standards individually.

Suitable online services
Publication date
2012-08
Original language
German
Pages
50
Procedure
Pre-Standard
DOI
https://dx.doi.org/10.31030/1900986

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

The application of re-usable medical devices that are of low microbiological contamination or are sterile intended for direct use on patients assumes a previous processing of such medical devices. In order to be able to produce this condition and maintain it up until use, the total process of re-processing under use of extensive quality assurance measures is required to run in correspondence with the state of the art. Therefore, defined requirements shall be placed on the processing. The conditions under which a medical device may be designated as "sterile" are specified in DIN EN 556-1. It shall be specified in accordance with the "Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten" ("Requirements on hygiene during processing of medical devices") of the Robert Koch Institute (RKI) which medical devices shall be sterile.
All individual processing steps shall be coordinated with respect to the medical device, the previous processing and the previous as well as subsequent use of the medical device and shall always ensure the fulfilment in a consistently comprehensible and reproducible manner by the application of validated methods.
The basic requirements for the development, validation and routine control of a sterilization process for medical devices are specified in DIN EN ISO 17665-1.
DIN SPEC 58929 (pre-standard) provides guidance and specifies requirements for validation and routine control of steam sterilization processes used in small sterilizers. For application in Type N processes in accordance with DIN EN 13060 parts of this pre-standard can be used analogously.
With this pre-standard the user and the operator of small steam sterilizers are provided with approaches which allow them - also under use of justifiable simplifications if applicable - to verify the specification-appropriate execution of the sterilization method as a validated part of the process method in accordance with the state of the art and with the applicable rules and regulations.
Working Committee NA 063-04-01 AA "Dampf-Sterilisatoren" ("Steam sterilizers") at the Medical Standards Committee is responsible at DIN, the German Institute for Standardization e. V.