Standard [WITHDRAWN]

DIN 18195-4:2011-12

Water-proofing of buildings - Part 4: Waterproofing against ground moisture (Capillary water, retained water) and non-accumulating seepage water under floor slabs on walls, design and execution

German title
Bauwerksabdichtungen - Teil 4: Abdichtungen gegen Bodenfeuchte (Kapillarwasser, Haftwasser) und nichtstauendes Sickerwasser an Bodenplatten und Wänden, Bemessung und Ausführung
Publication date
2011-12
Original language
German

Please select

from 44.60 EUR VAT included

from 41.68 EUR VAT excluded

Purchasing options

PDF download 1
  • 44.60 EUR

Shipment (3-5 working days) 1
  • 53.80 EUR

1

 Attention: Document withdrawn!

Abonnement im Online-Dienst

Diese Norm ist auch im praktischen Online-Dienst verfügbar. Im Online-Dienst stehen Ihnen Normensammlungen elektronisch zur Verfügung - angereichert mit vielen Extra-Infos (Richtlinien, Rechtstexte, Kommentare etc.) und mit regelmäßigen automatischen Updates. Im Vergleich zum Einzelerwerb der Normen ergeben sich deutliche Einsparungen.

Zu passenden Online-Diensten
Publication date
2011-12
Original language
German

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice 

All transactions are encrypted

Overview

The revision of the DIN 18195 standard series has become necessary, amongst others, due to the new European product standards, which affect in particular DIN 18195-2. As a result, this standard has been adapted to the European product standards in connection with the application standard DIN V 20000-202. Amendment A1:2011 has been incorporated into this edition. The start and finish of text introduced or altered by amendment are indicated in the text by tags. Complete incorporation of "new" materials in accordance with DIN 18195-2:2009-04, Tables 7, 8 and 9, for the scope of Part 4 takes place in the successor standards to DIN 18195. This standard applies to water-proofing of buildings and components with bituminous materials and plastic sheets against water present in the soil which is capillary bound and also transmittable against gravity (suction water, adhesive water, capillary water). It also applies to the water-proofing against non-accumulating seepage water originating from rainfall in case of vertical and undercut wall components. This moisture load can only be expected if both the fill material of the workspaces and the building site consist up to a sufficient depth under the bottom of foundation of extremely permeable soils, for example, sand and gravel (water permeability coefficient k higher than 10-4 according to DIN 18130-1) or if drainage systems according to DIN 4095, where long-term functionality is given, exist for less permeable soils. The committee responsible for this standard is NA 005-02-13 AA "Bauwerksabdichtungen (SpA zu CEN/TC 314)" (" Water-proofing of buildings (Mirror Committee of CEN/TC 314)") at DIN.