To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

DIN EN 62271-211:2014-12

VDE 0671-211:2014-12

High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (IEC 62271-211:2014); German version EN 62271-211:2014

German title
Hochspannungs-Schaltgeräte und -Schaltanlagen - Teil 211: Direkte Verbindungen zwischen Leistungstransformatoren und gasisolierten metallgekapselten Schaltanlagen für Bemessungsspannungen über 52 kV (IEC 62271-211:2014); Deutsche Fassung EN 62271-211:2014
Publication date
2014-12
Original language
German
Pages
26

Please select

63.27 EUR VAT included

59.13 EUR VAT excluded

Purchasing options

Shipment (3-5 working days)
  • 63.27 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2014-12
Original language
German
Pages
26

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This part of IEC 62271 applies to single-phase and three-phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchangeability and to determine the limits of supply of for the transformer connection. Direct connections are immersed on one end in the transformer oil or insulating gas and on the other end in the insulating gas of the switchgear. IEC 62271-211:2014 will replace IEC/TR 61639:1996. It is a technical revision which includes the following essential technical modifications with respect to the previous edition: a) transition from Technical Report to International Standard; b) the lowest rated voltage value has been modified from 72,5 kV to 52 kV; c) normative references have been updated; d) the term insulated connection/coupling including limitation of supply has been introduced; e) the dielectric testing of gas-insulated metal-enclosed switchgear for transformer connections in three-phase enclosures has been specified; f) tolerances of the contact face on the transformer side have been added; g) tolerances of the transformer in operation have been added; h) accidental loads for flange bushings have been added; i) oil and gas insulated transformers have been taken into account; j) three-phase enclosed direct connections have been included. The responsible committee is DKE/UK 432.2 "Typgeprüfte Hochspannungs-Schaltanlagen" ("Type-tested controlgear") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...